MENUMENU
  • Company
  • Solutions
    • Technology Solutions
    • Case Studies
  • Resources
    • Downloads
    • Videos
  • News
  • Rep Locator
  • Contact Us
  • PRO-FLOW ®
  • italian flag
  • other flag
ProtectosealProtectoseal
MENUMENU
  • Vapor & Flame Products
        • Pressure & Vacuum Relief Vents

          FAB Valve

          End-of-Line Conservation Vent and Flame Arrester

          830

          End-of-Line Conservation Vent and Flame Arrester

          830E

          End-of-Line Conservation Vent and Flame Arrester – ATEX / CE / ISO

          3908-SL

          Pressure and Vacuum Relief Thief Hatch

          5200G

          Weatherhood Free Vent

          6240

          End-of-Line Vacuum Vent

          8540G

          End-of-Line Pressure / Vacuum Conservation Vent – Improved Performance

          8540H

          End-of-Line Pressure / Vacuum Conservation Vent

          8740

          In-Line Pressure and Vacuum Relief Vent

          16240

          Side-Mounted Vacuum Relief Vent

          17800

          Pipe-Away Pressure Relief Vent

          18540D

          Pipe-Away Pressure and Vacuum Relief Ven

          56000

          PIN-TECH™ Bubble-Tight 500 ppm Pressure Relief Vent

          Spring Loaded Data Sheet
        • Emergency Relief Vents

          7800

          End-of-Line Emergency Pressure Vent

          51700

          Hinged Emergency Pressure Relief Manhole Cover Vent

          52600

          Emergency Pressure and Vacuum Relief Vent

          53300

          Emergency Pressure Relief Manhole Cover Ven

          54000

          Spring-Loaded Emergency Pressure Relief Vents

          Tank Blanketing Valves

          10

          Pilot Operated Tank Blanketing Valve, 2″

          20

          Pilot Operated Tank Blanketing Valve, 1″

          30

          Spring Operated Tank Blanketing Valve, ½″

        • Flame Arresters

          End-Of-Line Deflagration
          AVC

          Gas Groups: B, C & D |IIB & IIC

          EHB

          Gas Groups: C | IIB1, IIB2 & IIB

          ERB

          Gas Groups: D & C |IIA, IIA1, IIB1, IIB2 & IIB3

          ESA

          Gas Groups: D | IIA & IIA1

          EVA

          Gas Groups: D | IIA & IIA1

          EVB

          Gas Groups: C | IIB1, IIB2 & IIB3

          SV

          Gas Groups: D & C | IIA, IIA1, IIB1, IIB2 & IIB3

          670 / 6670

          Gas Groups: D|IIA

          670E

          Gas Groups: IIA, IIB3| D, C

          860

          Gas Groups: D|IIA

          Vent-Line / In-Line Deflagration
          LCA Series

          Gas Groups: D | IIA & IIA1

          LCB Series

          Gas Groups: C | IIB1, IIB2 & IIB3

          LEA Series

          Gas Groups: D | IIA & IIA1

          LEB Series

          Gas Groups: C | IIB1, IIB2 & IIB3

          4950

          Gas Groups: D|IIA

          30000

          Gas Groups: D|IIA

          In-Line Detonation
          UCA

          Gas Groups: D | IIA & IIA1

          UCB

          Gas Groups: C | IIB1, IIB2 & IIB3

          UEA

          Gas Groups: D | IIA & IIA1

          25000 / 26000

          Gas Groups: 25000 – D | IIA
          26000 – D, C | IIA, IIB3

          35000-36000RP

          Gas Groups: D, C | IIA, IIB3

          Other Equipment

          Liquid Level Monitoring

          Specialty Valves and Fittings

          Fuel Tank Safety Caps

  • Industries
        • Biogas

        • Terminals &
          Bulk Storage

        • Oil & Gas

          Offshore

        • Distilleries

        • Chemicals & 

          Petrochemicals

        • Pharmaceuticals

        • Fuel Distribution

        • Wineries

  • Tank Safety
        • Storage Tank Venting

        • Understanding / Specifying
          
Flame & Detonation Arresters

        • Tank Blanketing

        • Industry Regulations

        • Inspection & Maintenance Of Safety Equipment

        • Managing Tank
          
Pressure Safely

Search

Exploring Innovations in Flame Arresters

Michael Browner2024-03-20T07:10:18+00:00

In industries where flammable gases and liquids are handled, ensuring safety is paramount. Flame arresters play a crucial role in preventing the propagation of flames and explosions in such environments. These devices are designed to extinguish flames and limit the passage of ignited gases, thereby safeguarding personnel, equipment, and the environment.

Over the years, advancements in technology have led to the development of innovative flame arresters, enhancing their effectiveness and reliability. Here we share some of the notable innovations in flame arresters and their contributions to industrial safety.

Understanding Flame Arresters

Before delving into the latest innovations, let’s first understand the basic principles of flame arresters. Flame arresters are passive devices installed in pipelines, vents, or storage tanks to prevent the transmission of flames from flammable gases or vapors.

They principally consist of metal or other materials with narrow passages through which the flammable mixture must pass. When ignited, the flame front encounters the device, and various mechanisms within the arrester extinguish the flame by disrupting the combustion process.

Innovations in Flame Arresters

Traditional flame arresters are typically constructed using materials such as metal alloys or ceramics. The team at Protectoseal is constantly reviewing the material composition to introduce new options with superior properties. For instance, our flame arresters can be designed and supplied to operate at elevated temperatures with enhanced temperature resistance and higher levels of durability in corrosive environments to ensure improved performance and longevity.

Investments in technologies have also allowed Protectoseal to undertake fluid dynamics modelling, which involves explosion simulations, so we can enhance the designs and optimize the flame arrester’s performance. By employing advanced mathematical models and algorithms, engineers can analyse fluid flow, heat transfer, and combustion dynamics within the arrester. This allows for the refinement of design parameters such as passage geometry, spacing, and surface characteristics to ensure enhanced flow characteristics, optimum flame suppression efficiency, and minimum pressure drop.

One such example is Protectoseal’s E-Flow® technology, which is used in most of Protectoseal’s End-of-Line and In-Line Flame Arresters. The technology was developed after years of research and collaboration with customers to offer ultimate protection while also allowing for improved gas and vapor flow rates during normal operation while mitigating pressure drops.

Building on this technology, our engineers patented RE-Flow® technology as a combination of our E-Flow® technology with a reverse flow configuration. This technology is utilised in our ERB Series of End-of-Line Flame Arresters and is designed to improve the performance of our Flame Arresters by optimizing the flow and pressure drop characteristics. It incorporates our enhanced crimped ribbon technology in the flame arresting element, and the matrix structure is optimized using computational fluid dynamics (CFD).

Our in-house team of engineers has also developed our new patented HEDS® (High Energy Dissipation System) technology. The technology is used in our range of In-Line Detonation Flame Arresters and offers ultimate protection from deflagration and both stable and unstable detonation explosions. The flame arresters combine Protectoseal’s patented HEDS® with our E-Flow® technology. This combination attenuates shock waves and extinguishes flames, effectively mitigating the effects of an explosion by preventing its propagation.

Flame Arrester Modelling

Using modelling, our engineers can tailor flame arresters for specific applications with precision, resulting in optimized performance and reduced maintenance requirements.

Modern flame arresters often integrate with the monitoring and control systems of pipeline or tank operators for real-time performance assessment and enhanced safety management. These systems utilize sensors to detect parameters such as temperature, pressure, and flow rate, providing continuous feedback on the operating conditions. In the event of an anomaly or malfunction, automated shutdown mechanisms can be activated to isolate the source of the flame and prevent the escalation to a potentially catastrophic scenario.

This information can also be used to remotely monitor process performance, which, in turn, can be used for maintenance scheduling and compliance tracking to ensure the reliability and regulatory compliance of flame arrester installations.

Our innovative products are designed and manufactured in the UK, USA, and India and have been independently flame and explosion type-tested. These tests are certified to EN ISO 16852 (previously BS EN 12874), the European Standard for flame arresters, which provides for a significant safety margin in typical operating conditions.

Mitigate the Risks of Fire and Explosion

As industrial processes become increasingly complex and hazardous, investing in the very latest and best flame arrester technology is essential to mitigate the risks of fire and explosion in order to safeguard personnel, physical assets, and, of course, the environment.

At Protectoseal, investment and innovation continue to drive our advancements in flame arresters, enhancing their performance, reliability, and adaptability to diverse industrial environments. Our experienced technical team works closely with our customers to design bespoke, cost-effective, and innovative solutions that reflect the best materials, computer modelling, and design to meet the safety challenges of modern industries.

Contact a member of the team to discuss your requirements and let us show you how our world-leading flame arresters provide the ultimate protection from explosions in high-risk environments.

Contact us today to learn more.

  • Vapor and Flame Solutions
    • Pressure and Vacuum Vents
      • FAB
        End-of-Line Pressure/Vacuum Conservation Vent and Flame Arrester
      • 830
        End-of-Line Conservation Vent and Flame Arrester
      • 830E
        End-of-Line Conservation Vent and Flame Arrester – ATEX / CE / ISO
      • 3908
        Pressure and Vacuum Relief Thief Hatch
      • 5200G
        Weatherhood Free Vent
      • 6240
        End-of-Line Vacuum Vent
      • 8540G
        End-of-Line Pressure / Vacuum Conservation Vent – Improved Performance
      • 8540H
        End-of-Line Pressure / Vacuum Conservation Vent
      • 8740
        In-Line Pressure and Vacuum Relief Vent
      • 16240
        Side-Mounted Vacuum Relief Vent
      • 17800
        Pipe-Away Pressure Relief Vent
      • 18540D
        Pipe-Away Pressure and Vacuum Relief Vent
      • 56000
        PIN-TECH™ Bubble-Tight <500 ppm Pressure Relief Vent
      • Spring Loaded Vents
    • Emergency Relief Vents
      • 7800
        End-of-Line Emergency Pressure Vent
      • 51700
        Hinged Emergency Pressure Relief Manhole Cover Vent
      • 52600
        Emergency Pressure and Vacuum Relief Vent
      • 53300
        Emergency Pressure Relief Manhole Cover Vent
      • 54000
        Spring-Loaded Emergency Pressure Relief Vents
    • Flame Arresters
      • End-of-Line Deflagration Flame Arresters
        • AVC
          Gas Groups: B, C & D |IIB & IIC
        • EHB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • ERB
          Gas Groups: D & C |IIA, IIA1, IIB1, 
IIB2 & IIB3
        • ESA
          Gas Groups: D | IIA & IIA1
        • EVA
          Gas Groups: D | IIA & IIA1
        • EVB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • SV
          Gas Groups: D & C | IIA, 
IIA1, IIB1, IIB2 & IIB3
        • 670 / 6670
          Gas Groups: D|IIA
        • 670E
          Gas Groups: IIA, IIB3| D, C
        • 860
          Gas Groups: D|IIA
        • 27000 / 29000 / 31000
      • Vent-Line / In-Line Deflagration Flame Arresters
        • LCA
          Gas Groups: D | IIA & IIA1
        • LCB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • LEA
          Gas Groups: D | IIA & IIA1
        • LEB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • 4950
          Gas Groups: D|IIA
        • 30000
          Gas Groups: D|IIA
        • 45000E / 46000E
          Gas Groups: IIA, IIB3 | D, C
      • In-Line Detonation Flame Arresters
        • UCA
          Gas Groups: D | IIA & IIA1
        • UCB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • UEA
          Gas Groups: D | IIA & IIA1
        • 25000 / 26000
          Gas Groups: D, C | IIA, IIB3
        • 25000E / 35000E
          Gas Groups: IIA | D
        • 26000E / 36000E
          Gas Groups: IIA, IIB3 | D, C
        • 35000 / 36000RP
          Gas Groups: D, C | IIA, IIB3
    • Tank Blanketing Valves
      • 10
        Pilot Operated Tank Blanketing Valve, 2″
      • 20
        Pilot Operated Tank Blanketing Valve, 1″
      • 30
        Spring Operated Tank Blanketing Valve, ½″
    • Other Equipment
      • Liquid Level Monitoring
      • Specialty Valves and Fittings
      • Fuel Tank Safety Caps
  • Industries
    • Biogas Product Guide
    • Terminals & Bulk Storage Product Guide
    • Oil & Gas Offshore Product Guide
    • Distilleries Product Guide
    • Petrochemicals Product Guide
    • Pharmaceuticals Product Guide
    • Fuel Distribution Product Guide
    • Wineries Product Guide
  • Tank Safety
    • Storage Tank Venting
    • Understanding / Specifying Flame and Detonation Arresters
    • Tank Blanketing
    • Industry Regulations
    • Inspection & Maintenance 
 Of Safety Equipment
    • Manage Tank Pressure Safely

Solutions

Flame Arrester Solutions

Download this Video
View Other Videos

Distilled Spirits

Download the Full Story
View Other Solutions

Product Quick Find

Find product information and
availlable documentation downloads.

Our Locations

USA

The Protectoseal Company
(Headquarters)

225 Foster Avenue,
Bensenville,
Illinois, 60106, USA

Tel: +1 630 595 0800

Fax: +1 630 595 8059
Email: info@protectoseal.com

UK

Elmac Technologies Ltd.
T/A Protectoseal

Coast Road,
Greenfield,
Flintshire,
CH8 9DP, UK

Tel: +44 1352 717 560

Email: enquiries@protectoseal.uk

INDIA

Elmac Envisafe Technologies
Pvt. Ltd. T/A Protectoseal

701, Tropical New Era
Business Park, Road No.33,
Wagle industrial Estate,
Maharashtra, 400604, IN
Tel: +91 22 4100 6998
Email: sales.eet@protectoseal.in

Need Assistance

Get help from your representative and find the best solution to fit your needs.

“It is a pleasure to collaborate with the Protectoseal Team! They are extremely helpful, and their products are excellent; we wouldn’t go anyplace else.”

Process Engineering ManagerGlobal Bulk Chemical Storage Company, UK

Vapor and Flame Solutions

  • Pressure and Vacuum Relief Vents
  • Emergency Relief Vent
  • Flame and Detonation Arresters
  • Tank Blanketing Valves

Complementary Equipment

  • Liquid Level Monitoring
  • Specialty Valves and Fittings
  • Fuel Tank Safety Caps

Company

Technology Solutions

About Us

Industries

Downloads

Rep Locator

News and Events

ProFlow

Certifications

Youtube Linkedin

Copyright © The Protectoseal Company.
All Right Reserved

Terms of Use | Credit Application

MENUMENU
  • Vapor & Flame Products
        • Pressure & Vacuum Relief Vents

          FAB Valve

          End-of-Line Conservation Vent and Flame Arrester

          830

          End-of-Line Conservation Vent and Flame Arrester

          830E

          End-of-Line Conservation Vent and Flame Arrester – ATEX / CE / ISO

          3908-SL

          Pressure and Vacuum Relief Thief Hatch

          5200G

          Weatherhood Free Vent

          6240

          End-of-Line Vacuum Vent

          8540G

          End-of-Line Pressure / Vacuum Conservation Vent – Improved Performance

          8540H

          End-of-Line Pressure / Vacuum Conservation Vent

          8740

          In-Line Pressure and Vacuum Relief Vent

          16240

          Side-Mounted Vacuum Relief Vent

          17800

          Pipe-Away Pressure Relief Vent

          18540D

          Pipe-Away Pressure and Vacuum Relief Ven

          56000

          PIN-TECH™ Bubble-Tight 500 ppm Pressure Relief Vent

          Spring Loaded Data Sheet
        • Emergency Relief Vents

          7800

          End-of-Line Emergency Pressure Vent

          51700

          Hinged Emergency Pressure Relief Manhole Cover Vent

          52600

          Emergency Pressure and Vacuum Relief Vent

          53300

          Emergency Pressure Relief Manhole Cover Ven

          54000

          Spring-Loaded Emergency Pressure Relief Vents

          Tank Blanketing Valves

          10

          Pilot Operated Tank Blanketing Valve, 2″

          20

          Pilot Operated Tank Blanketing Valve, 1″

          30

          Spring Operated Tank Blanketing Valve, ½″

        • Flame Arresters

          End-Of-Line Deflagration
          AVC

          Gas Groups: B, C & D |IIB & IIC

          EHB

          Gas Groups: C | IIB1, IIB2 & IIB

          ERB

          Gas Groups: D & C |IIA, IIA1, IIB1, IIB2 & IIB3

          ESA

          Gas Groups: D | IIA & IIA1

          EVA

          Gas Groups: D | IIA & IIA1

          EVB

          Gas Groups: C | IIB1, IIB2 & IIB3

          SV

          Gas Groups: D & C | IIA, IIA1, IIB1, IIB2 & IIB3

          670 / 6670

          Gas Groups: D|IIA

          670E

          Gas Groups: IIA, IIB3| D, C

          860

          Gas Groups: D|IIA

          Vent-Line / In-Line Deflagration
          LCA Series

          Gas Groups: D | IIA & IIA1

          LCB Series

          Gas Groups: C | IIB1, IIB2 & IIB3

          LEA Series

          Gas Groups: D | IIA & IIA1

          LEB Series

          Gas Groups: C | IIB1, IIB2 & IIB3

          4950

          Gas Groups: D|IIA

          30000

          Gas Groups: D|IIA

          In-Line Detonation
          UCA

          Gas Groups: D | IIA & IIA1

          UCB

          Gas Groups: C | IIB1, IIB2 & IIB3

          UEA

          Gas Groups: D | IIA & IIA1

          25000 / 26000

          Gas Groups: 25000 – D | IIA
          26000 – D, C | IIA, IIB3

          35000-36000RP

          Gas Groups: D, C | IIA, IIB3

          Other Equipment

          Liquid Level Monitoring

          Specialty Valves and Fittings

          Fuel Tank Safety Caps

  • Industries
        • Biogas

        • Terminals &
          Bulk Storage

        • Oil & Gas

          Offshore

        • Distilleries

        • Chemicals & 

          Petrochemicals

        • Pharmaceuticals

        • Fuel Distribution

        • Wineries

  • Tank Safety
        • Storage Tank Venting

        • Understanding / Specifying
          
Flame & Detonation Arresters

        • Tank Blanketing

        • Industry Regulations

        • Inspection & Maintenance Of Safety Equipment

        • Managing Tank
          
Pressure Safely

  • Vapor and Flame Solutions
    • Pressure and Vacuum Vents
      • FAB
        End-of-Line Pressure/Vacuum Conservation Vent and Flame Arrester
      • 830
        End-of-Line Conservation Vent and Flame Arrester
      • 830E
        End-of-Line Conservation Vent and Flame Arrester – ATEX / CE / ISO
      • 3908
        Pressure and Vacuum Relief Thief Hatch
      • 5200G
        Weatherhood Free Vent
      • 6240
        End-of-Line Vacuum Vent
      • 8540G
        End-of-Line Pressure / Vacuum Conservation Vent – Improved Performance
      • 8540H
        End-of-Line Pressure / Vacuum Conservation Vent
      • 8740
        In-Line Pressure and Vacuum Relief Vent
      • 16240
        Side-Mounted Vacuum Relief Vent
      • 17800
        Pipe-Away Pressure Relief Vent
      • 18540D
        Pipe-Away Pressure and Vacuum Relief Vent
      • 56000
        PIN-TECH™ Bubble-Tight <500 ppm Pressure Relief Vent
      • Spring Loaded Vents
    • Emergency Relief Vents
      • 7800
        End-of-Line Emergency Pressure Vent
      • 51700
        Hinged Emergency Pressure Relief Manhole Cover Vent
      • 52600
        Emergency Pressure and Vacuum Relief Vent
      • 53300
        Emergency Pressure Relief Manhole Cover Vent
      • 54000
        Spring-Loaded Emergency Pressure Relief Vents
    • Flame Arresters
      • End-of-Line Deflagration Flame Arresters
        • AVC
          Gas Groups: B, C & D |IIB & IIC
        • EHB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • ERB
          Gas Groups: D & C |IIA, IIA1, IIB1, 
IIB2 & IIB3
        • ESA
          Gas Groups: D | IIA & IIA1
        • EVA
          Gas Groups: D | IIA & IIA1
        • EVB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • SV
          Gas Groups: D & C | IIA, 
IIA1, IIB1, IIB2 & IIB3
        • 670 / 6670
          Gas Groups: D|IIA
        • 670E
          Gas Groups: IIA, IIB3| D, C
        • 860
          Gas Groups: D|IIA
        • 27000 / 29000 / 31000
      • Vent-Line / In-Line Deflagration Flame Arresters
        • LCA
          Gas Groups: D | IIA & IIA1
        • LCB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • LEA
          Gas Groups: D | IIA & IIA1
        • LEB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • 4950
          Gas Groups: D|IIA
        • 30000
          Gas Groups: D|IIA
        • 45000E / 46000E
          Gas Groups: IIA, IIB3 | D, C
      • In-Line Detonation Flame Arresters
        • UCA
          Gas Groups: D | IIA & IIA1
        • UCB
          Gas Groups: C | IIB1, IIB2 & IIB3
        • UEA
          Gas Groups: D | IIA & IIA1
        • 25000 / 26000
          Gas Groups: D, C | IIA, IIB3
        • 25000E / 35000E
          Gas Groups: IIA | D
        • 26000E / 36000E
          Gas Groups: IIA, IIB3 | D, C
        • 35000 / 36000RP
          Gas Groups: D, C | IIA, IIB3
    • Tank Blanketing Valves
      • 10
        Pilot Operated Tank Blanketing Valve, 2″
      • 20
        Pilot Operated Tank Blanketing Valve, 1″
      • 30
        Spring Operated Tank Blanketing Valve, ½″
    • Other Equipment
      • Liquid Level Monitoring
      • Specialty Valves and Fittings
      • Fuel Tank Safety Caps
  • Industries
    • Biogas Product Guide
    • Terminals & Bulk Storage Product Guide
    • Oil & Gas Offshore Product Guide
    • Distilleries Product Guide
    • Petrochemicals Product Guide
    • Pharmaceuticals Product Guide
    • Fuel Distribution Product Guide
    • Wineries Product Guide
  • Tank Safety
    • Storage Tank Venting
    • Understanding / Specifying Flame and Detonation Arresters
    • Tank Blanketing
    • Industry Regulations
    • Inspection & Maintenance 
 Of Safety Equipment
    • Manage Tank Pressure Safely
MENUMENU
  • Company
  • Solutions
    • Technology Solutions
    • Case Studies
  • Resources
    • Downloads
    • Videos
  • News
  • Rep Locator
  • Contact Us
  • PRO-FLOW ®